GX2CrNiMoN25-6-3 (EN 1.4468) Duplex Stainless Steel Casting Material
Duplex Stainless Steel
Introduction
EN 10283, EN 10340 and ISO 11972 Grade GX2CrNiMoN25-6-3 is a duplex stainless steel casting grade. Process options include investment casting, shell molding and sand casting. Typical family applications include pump casings, impellers, covers and valve bodies.
| Field | Value |
|---|---|
| Designation | GX2CrNiMoN25-6-3 (EN 1.4468) |
| Material Type | Stainless Steel |
| Sub Type | Duplex Stainless Steel |
| Product Form | casting |
Manufacturing Process
Investment Casting
Shell Molding Casting
Sand Casting
Equivalent Materials
Not Available
Similar Materials
Not Available
Reference Standards
Related Casting Products
Physical Properties
EN 10283 — 2019
| Property | Value | Applicable Conditions |
|---|---|---|
| Density | 7.7 kg/dm³[1] | Test temperature: 20 °C |
| Thermal Conductivity | 17 W/(m·K)[1] | Test temperature: 50 °C |
| Thermal Conductivity | 18 W/(m·K)[1] | Test temperature: 100 °C |
| Specific Heat | 450 J/(kg·K)[1] | Test temperature: 20 °C |
| Thermal Expansion | 13 ×10⁻⁶/K[1] | Temperature range: 20–100 °C |
| Thermal Expansion | 14 ×10⁻⁶/K[1] | Temperature range: 20–300 °C |
Notes
- [1] Informative values; not mandatory acceptance limits.
Chemical Composition
| Element | EN 10283 — 2019 | EN 10340 — 2007 | ISO 11972 — 2023 |
|---|---|---|---|
| C | ≤ 0.030 %[1] | ≤ 0.030 %[1] | ≤ 0.03 % |
| Si | ≤ 1.00 %[1] | ≤ 1.00 %[1] | ≤ 1.0 % |
| Mn | ≤ 2.00 %[1] | ≤ 2.00 %[1] | ≤ 2.00 % |
| P | ≤ 0.035 %[1] | ≤ 0.035 %[1] | ≤ 0.035 % |
| S | ≤ 0.025 %[1] | ≤ 0.025 %[1] | ≤ 0.025 % |
| Cr | 24.50–26.50 %[1] | 24.50–26.50 %[1] | 24.5–26.5 % |
| Ni | 5.50–7.00 %[1] | 5.50–7.00 %[1] | 5.5–7.0 % |
| Mo | 2.50–3.50 %[1] | 2.50–3.50 %[1] | 2.50–3.50 % |
| Cu | ≤ 0.50 %[2] | ≤ 0.50 %[1] | Not Available |
| N | 0.12–0.25 %[1] | 0.12–0.25 %[1] | 0.12–0.25 % |
Notes
- [1] C, Si, Mn, P, S, Cr, Mo, Ni, N (EN 10283:2019 only); EN 10340:2007: cast analysis
- [2] Cu (EN 10283:2019 only): Applies unless otherwise agreed; unspecified elements shall not be intentionally added without purchaser agreement except for finishing the heat.; cast analysis
Heat Treatment
EN 10283 — 2019
| Heat Treatment | Operation | Temperature | Cooling |
|---|---|---|---|
| +AT | solution annealing | 1120–1150 °C | water |
EN 10340 — 2007
| Heat Treatment | Operation | Temperature | Cooling |
|---|---|---|---|
| +AT | solution annealing[1] | 1120–1150 °C | water |
Notes
- [1] Informative values; not mandatory acceptance limits.
ISO 11972 — 2023
| Heat Treatment | Operation | Temperature | Cooling |
|---|---|---|---|
| Solution treated | solution treatment[1] | 1120–1150 °C | quench in water |
Notes
- [1] After high-temperature solution annealing, optional cooling from 1040 °C to 1010 °C before water quenching may prevent cracks in complex shapes.
Mechanical Properties
Primary Mechanical Properties
EN 10283 — 2019
Condition: t ≤ 150 mm; Room temperature; +AT
| Property | Requirement |
|---|---|
| Yield Strength (Rp0.2) | ≥ 480 MPa[1][2][3] |
| Tensile Strength | ≥ 650 MPa[1][2][3] |
| Elongation | ≥ 22 %[1][2][3] |
| Impact Energy | ≥ 50 J[1][2][3][4] |
Notes
- [1] Test block
- [2] maximum thickness 150 mm
- [3] Yield and tensile strength also apply to the casting up to the maximum specified wall thickness.
- [4] Impact Energy: KV2 as specified in Table 2
EN 10340 — 2007
Condition: t ≤ 150 mm; Room temperature; +AT
| Property | Requirement |
|---|---|
| Yield Strength (Rp0.2) | ≥ 480 MPa[1][2][3] |
| Tensile Strength | 650–850 MPa[1][2][3] |
| Elongation | ≥ 22 %[1][2][3] |
| Impact Energy | ≥ 50 J[1][2][3] |
Notes
- [1] Test block of relevant thickness
- [2] maximum thickness 150 mm
- [3] Yield and tensile strength also apply to the casting up to the maximum relevant wall thickness.
ISO 11972 — 2023
Condition: t ≤ 150 mm; Room temperature; Solution treated
| Property | Requirement |
|---|---|
| Yield Strength (Rp0.2) | ≥ 480 MPa[1] |
| Tensile Strength | ≥ 650 MPa[1] |
| Elongation | ≥ 22 %[1] |
| Impact Energy | ≥ 50 J[1][2] |
Notes
- [1] Test blocks used to verify mechanical properties shall not exceed 150 mm thickness. Properties for samples removed from castings shall be agreed between manufacturer and purchaser.
- [2] Impact Energy: Verification of impact tests is required only when indicated by the customer.
Welding Conditions
EN 10283 — 2019
| Property | Value |
|---|---|
| Preheat | 20–100 °C[1][4] |
| Interpass Temperature | ≤ 250 °C[4] |
| Post-weld Heat Treatment | Solution annealing followed by water quenching[2][4] |
| Post-weld Heat Treatment | Solution annealing followed by water quenching[3][4] |
Notes
- [1] Preheat: Preheat depends on casting geometry, thickness and climatic conditions.
- [2] Post-weld Heat Treatment (EN 10283:2019 only): minor welds; Air quenching may be agreed for very small, thin castings according to corrosion conditions. With low preheat and interpass temperatures (≤150 °C), post-weld heat treatment may be suppressed by agreement.
- [3] Post-weld Heat Treatment (EN 10283:2019 only): major welds; Air quenching may be agreed for very small, thin castings according to corrosion conditions.
- [4] Informative values; not mandatory acceptance limits.
EN 10340 — 2007
| Property | Requirement |
|---|---|
| Preheat | 20–100 °C[1] |
| Interpass Temperature | ≤ 250 °C |
| Post-weld Heat Treatment | Solution annealing and water quenching[2] |
Notes
- [1] Preheat: Preheat depends on casting geometry, thickness and climatic conditions.
- [2] Post-weld Heat Treatment: For minor welds, special arrangements may be agreed according to corrosion conditions; production welds are generally major when cavity depth exceeds 40% of wall thickness. With low preheat and interpass temperatures (≤150 °C), post-weld heat treatment may be suppressed by agreement. Air quenching may be agreed for very small, thin castings according to corrosion conditions. Special arrangements may be agreed according to corrosion conditions.
Applications
Typical applications for this corrosion-resistant steel casting family include components exposed to corrosive environments in general engineering service. Other cast components used in this material family include pump casings, impellers, covers and valve bodies. Applications include water treatment, chemical processing, selected marine systems, desalination and pulp-and-paper pumping equipment.
The appropriate duplex grade depends on the actual water chemistry and operating conditions.
Need GX2CrNiMoN25-6-3 Castings?
Contact us for casting and machining inquiries.