GGG-40.3 (EN 0.7043) Ductile Cast Iron Casting Material

Ductile Cast Iron

Download MDS PDF · Request a Quote

Introduction

GGG-40.3 is a ductile cast iron grade covered by DIN 1693-1, DIN 1693-2. Typical family applications include gear and transmission components, hubs, brackets, machine housings and pump-related castings.

FieldValue
DesignationGGG-40.3 (EN 0.7043)
Material TypeCast Iron
Sub TypeDuctile Cast Iron
Product Formcasting

Manufacturing Process

Sand Casting
Shell Molding Casting
Lost Foam Casting

Equivalent Materials

N/A

Similar Materials

N/A

Reference Standards

StandardStandard TitleEditionSpecificationIdentifier
DIN 1693-1Cast Iron with Nodular Graphite — Unalloyed and Low Alloy Grades1973-10GGG-40.3—
DIN 1693-2Cast Iron with Nodular Graphite — Unalloyed and Low Alloy Grades — Properties in Cast-on Test Piece1977-10GGG-40.3—

Physical Properties

PropertyValue / UnitNoteSource
Density7.2 kg/dm³Approximate density for weight calculations, not a guaranteed density limitDIN 1693-1

Chemical Composition

DIN 1693-1–1973-10

No specified chemical composition limits in DIN 1693-1

DIN 1693-2–1977-10

N/A

Heat Treatment

DIN 1693-1–1973-10

Supplied as cast or heat-treated; no mandatory numerical heat-treatment cycle specified.

DIN 1693-2–1977-10

N/A

Mechanical Properties

Core Mechanical Properties

DIN 1693-1 — 1973-10 · Table 2 — Normative

PropertySeparately cast test piece
Tensile Strength≥ 400 N/mm2[1]
Yield Strength (Rp0.2)≥ 250 N/mm2[1]
Elongation≥ 18 %[1]
Impact Energy (DVM)≥ 16 J[2]
≥ 14 J[3]

DIN 1693-2 — 1977-10 · Table 1 — Normative

PropertyCast-on test piece
Tensile Strength≥ 390 N/mm2[4]
≥ 370 N/mm2[5]
Yield Strength (Rp0.2)≥ 250 N/mm2[4]
≥ 240 N/mm2[5]
Elongation≥ 15 %[4]
≥ 12 %[5]
Notes
  • Primarily casting weights >2000 kg and/or sections 50–200 mm; other sizes need separate agreement. Table 1 specifically lists 30–60 and >60–200 mm.

Additional Mechanical Properties

Low-Temperature Properties

DIN 1693-1 — 1973-10 · Table 2 — Normative

PropertySeparately cast test piece
Impact Energy (DVM)≥ 14 J[6]
≥ 11 J[7]

DIN 1693-2 — 1977-10 · Table 1 — Normative

PropertyCast-on test piece
Impact Energy (DVM)≥ 14 J[8]
≥ 11 J[9]
≥ 12 J[10]
≥ 9 J[11]
Notes
  • Primarily casting weights >2000 kg and/or sections 50–200 mm; other sizes need separate agreement. Table 1 specifically lists 30–60 and >60–200 mm.

Notes

DIN 1693-1 · Edition 1973-10

[1] Tensile Strength/Yield Strength (Rp0.2)/Elongation: Separately cast U or Y test piece; tensile specimen per DIN 50125; A5 elongation

[2] Impact Energy (DVM): DVM notched-bar impact specimen per DIN 50115; room temperature; no numeric temperature invented; Condition: Separately cast test piece; DVM specimens; not a Charpy V-notch conversion. Mean of 3 DVM specimens; DIN 1693-1:1973-10, Table 2, PDF page 2; Mean of 3 DVM specimens

[3] Impact Energy (DVM): DVM notched-bar impact specimen per DIN 50115; room temperature; no numeric temperature invented; Condition: Separately cast test piece; DVM specimens; not a Charpy V-notch conversion. Individual DVM specimen; DIN 1693-1:1973-10, Table 2, PDF page 2; Individual DVM specimen

[6] Impact Energy (DVM): Test at -20 °C; DVM notched-bar impact specimen per DIN 50115; -20 °C; Condition: Separately cast test piece; DVM specimens; not a Charpy V-notch conversion. Mean of 3 DVM specimens; DIN 1693-1:1973-10, Table 2, PDF page 2; Mean of 3 DVM specimens

[7] Impact Energy (DVM): Test at -20 °C; DVM notched-bar impact specimen per DIN 50115; -20 °C; Condition: Separately cast test piece; DVM specimens; not a Charpy V-notch conversion. Individual DVM specimen; DIN 1693-1:1973-10, Table 2, PDF page 2; Individual DVM specimen

DIN 1693-2 · Edition 1977-10

[4] Tensile Strength/Yield Strength (Rp0.2)/Elongation: wall thickness ≤ 60 mm; Cast-on test piece 40 mm; DIN 50125 B14x70 tensile specimen; A5 elongation

[5] Tensile Strength/Yield Strength (Rp0.2)/Elongation: wall thickness ≤ 200 mm; Cast-on test piece 70 mm; DIN 50125 B14x70 tensile specimen; A5 elongation

[8] Impact Energy (DVM): wall thickness ≤ 60 mm; Test at -20 °C; DVM impact specimen per DIN 50115; Condition: Cast-on test piece; 30 ≤ t ≤ 60 mm; DVM impact energy at -20 °C; other temperatures require agreement.; DIN 1693-2:1977-10, Table 1, PDF page 7; Mean of 3 DVM specimens

[9] Impact Energy (DVM): wall thickness ≤ 60 mm; Test at -20 °C; DVM impact specimen per DIN 50115; Condition: Cast-on test piece; 30 ≤ t ≤ 60 mm; DVM impact energy at -20 °C; other temperatures require agreement.; DIN 1693-2:1977-10, Table 1, PDF page 7; Individual DVM specimen

[10] Impact Energy (DVM): wall thickness ≤ 200 mm; Test at -20 °C; DVM impact specimen per DIN 50115; Condition: Cast-on test piece; 60 < t ≤ 200 mm; DVM impact energy at -20 °C; other temperatures require agreement.; DIN 1693-2:1977-10, Table 1, PDF page 7; Mean of 3 DVM specimens

[11] Impact Energy (DVM): wall thickness ≤ 200 mm; Test at -20 °C; DVM impact specimen per DIN 50115; Condition: Cast-on test piece; 60 < t ≤ 200 mm; DVM impact energy at -20 °C; other temperatures require agreement.; DIN 1693-2:1977-10, Table 1, PDF page 7; Individual DVM specimen

Welding Conditions

N/A

Applications

Typical cast components in this material family include gear and transmission components, hubs, brackets, machine housings and pump-related castings. Applications include agricultural, construction and general industrial machinery. Lifting, low-temperature and pressure-retaining duties require the relevant component-specific requirements; ordinary family uses do not establish those capabilities.

Need GGG-40.3 Castings?

Contact us for casting and machining inquiries.